浙江万能达炉业有限公司
手 机: 13705828806
电 话:0572-6871999 6087213 6870511
传 真:0572-6087105
E-mail:1390003299@qq.com
地 址:浙江省长兴县林城工业园区鼎兴北路6号(林城高速路口下20米左侧)
为我们节省电气电炉工程师们的时间和精力,现将中频炉技术参数翻译英文希望查阅。
5吨中频炉 5 ton intermediate frequency furnace
5吨/2500KW/350Hz中频炉(12脉中频炉)5 ton/2500KW/350Hz 24 pulse intermediate frequency furnace(12 pulse)
设计由功率为2500 kw的12脉中频电源1套配5吨中频炉两台,其中一用一备。用一台2500KVA专用整流变压器供2500KW中频电源使用,用于用于熔炼炉熔炼。
此套中频炉符合GB5959.3《电热设备的安全第三部分对感应和导电加热设备以及感应熔炼设备的特殊要求》、GB10067.3《电热设备基本技术条件第三部分感应电热设备》和JB42《中频无芯感应炉》的要求。
Our company designed 6000kW 12 pulse intermediate frequency power source supplied with two 5-ton intermediate frequency melting furnace,one with a preparation。The 2500KW intermediate frequency power are supplied with 2500KVA special rectifier transformer for melting。The set of intermediate frequency furnace conforms standards of GB5959.3-《Part III of the safety of electrical equipment for induction and conduction heating and induction melting equipment under special requirements》,GB10067.3-《Part III of electric equipment basic technical conditions for induction heating equipment》,and JB42- 《Intermediate frequency Coreless Induction Furnace》。
5吨/2500KW中频炉设备主要技术参数要求
序号 |
项 目 |
参 数 |
备 注 |
1 |
电源进线电压 |
1000V ,50Hz |
用户电网电压10KV |
2 |
额定容量 |
5T |
2500KW功率熔炼 |
3 |
额定功率 |
2500KW |
6相12脉中频电源 |
4 |
额定中频频率 |
250 Hz |
|
5 |
额定温度 |
1650℃ |
|
6 |
熔化率 |
约5T/H |
中频炉连续使用 |
7 |
单位电耗 |
约620-650kwh/T |
中频炉连续使用 |
8 |
电源冷却循环水耗量 |
5T/H |
中频炉连续使用 |
炉体冷却循环水耗量 |
5T/H |
中频炉连续使用 |
|
9 |
液压站容量 |
200 L |
|
10 |
变压器型号 |
ZSS-4000 /10KV/1250 |
专用整流变压器(供1250KW) |
11 |
液压介质 |
46号液压油 |
|
12 |
供水压力 |
0.2-0.3 MPa |
到电炉端口位置 |
13 |
液压站工作压力 |
15 MPa |
最高18 MPa |
14 |
进水温度 |
£35℃ |
|
15 |
出水温度 |
£55℃ |
|
5吨/2500KW中频熔炼炉(钢壳)成套设备标准配置表:
序 号 |
名 称 |
型号 , 及备注 |
数量 |
价格 |
一) 一套5吨中频感应电炉成套供货范围及报价 |
||||
1 |
中频电源柜 |
2500KW配5吨中频熔炼炉 |
1套 |
|
2 |
电容器组 |
|||
3 |
漏炉报警装置 |
|||
4 |
炉体(包括:油缸、铁芯、支架、感应线圈等 ) |
5吨熔炼炉体 |
1套 |
|
5 |
坩埚模 |
|
||
6 |
水冷电缆 |
水冷电缆侧出线 |
2套 |
|
7 |
液压站系统 |
|
1套 |
|
8 |
倾炉操纵台 |
力士乐系列元件 |
1套 |
|
9 |
设备技术图纸 |
|
1套 |
|
10 |
设备使用说明书 |
|
1套 |
|
11 |
合格证及检验报告 |
|
1套 |
|
12 |
中频炉维修维护保修期 |
|
1年 |
|
合计 |
全套设备总价格为: 万 |
备注:
1)用6相12脉中频电源。消除了5、7高次谐波,大大减少了电网的谐波干扰。
2)采用全封闭式冷却塔提可提高系统的冷却效果和设备的使用寿命,无须建水池。
3)06年以来我公司出口到瑞典,挪威,、拉托维亚,并大量出口到非洲,东南亚等国家.
5 ton/2500KW intermediate frequency furnace main technical parameters
NO. |
Item |
Index |
Notes |
1 |
Line voltage |
1000V ,50Hz |
Grid voltage 10KV |
2 |
Rated capacity |
5T |
2500KW power of melting |
3 |
Rated power |
2500KW |
6 phase 12 pulse intermediate frequency power source |
4 |
Rated frequency |
250 Hz |
|
5 |
Rated temperature |
1650℃ |
|
6 |
Melting rate |
About 5T/H |
Continuous use |
7 |
Unit energy consumption |
About 620-650kwh/T |
Continuous use |
8 |
Power source cooling water consumption |
5T/H |
Continuous use |
Furnace cooling water consumption |
5T/H |
Continuous use |
|
9 |
Capacity of hydraulic station |
200 L |
|
10 |
Transformer |
ZSS-4000 /10KV/1250 |
Special rectifier transformer(supply 1250KW) |
11 |
Hydraulic medium |
46# Hydraulic oil |
|
12 |
Water supply pressure |
0.2-0.3 MPa |
To electric port location |
13 |
Working pressure of hydraulic station |
15 MPa |
Up to 12 MPa |
14 |
Inlet water temperature |
£35℃ |
|
15 |
Qotlet water temperature |
£55℃ |
|
5ton/6000KW intermediate frequency furnace standard configuration table
NO. |
Name |
Models and notes |
Number |
Price |
|
A 5-ton intermediate frequency induction furnace set scope of supply and pricing |
|||||
1 |
Intermediate-frequency power source Cabinet |
6300KW with 10 ton intermediate frequency melting furnace |
1 set |
|
|
2 |
Capacitor |
||||
3 |
Furnace leakage alarm |
||||
4 |
Furnace (includes: cylinder, core, support, Induction coil, etc) |
10T Melting furnace |
1 set |
||
5 |
Crucible mould |
|
|||
6 |
Water cooled cables |
Water cooled cable side outlet |
2 set |
||
7 |
Hydraulic system |
|
1 set |
||
8 |
Tilting furnace Control Panel |
Rexroth series components |
1 set |
||
9 |
Re-designing |
|
1 set |
|
|
10 |
Instructions for use |
|
1 set |
||
11 |
Certificates and test reports |
|
1 set |
||
Total |
Total price of a full set |
1)6 phase 12 pulse intermediate frequency power source control system can eliminate 5, 7high-order harmonic,and significantly reduces the power grid harmonic interference。
2)Closed circuit cooling tower is used to improve the effect of the cooling system and equipment service life,without building the pool.
3) Since 2006, our company exports to Sweden, Norway, and Latvia, Africa, Southeast Asia and other countries.
http://www.minglusc.com/BdwlkjNews.asp?id=845